Skip to main content
Linkedalu Metal Group Co., Ltd LINKEDALU Metal Group
Aluminium profiles for a louvered pergola roof, including posts, beams and louver blades

We extrude the parts that make a louvered roof: posts, main beams, blades, the gutter that sits inside the beam, seal retainers and end caps. Blades run from 130 to 265 mm, structural profiles from 2.0 to 3.0 mm wall, in 6063-T5 or T6, cut to your list and finished anodised or powder coated. We supply profiles. Motors, screens, glass and installation stay with you.

Two things decide whether a louvered roof still works after the second rainy season: where the water goes when the blades are closed, and whether a blade can be fitted the wrong way up. Both are settled in the section drawing, long before anyone stands on a ladder.

What Does a Roof Set Contain?

A complete louvered roof is not one profile. It is a small family of sections that have to fit each other, and each one carries a decision.

ProfileWhat it doesWhat the drawing has to fix
PostCarries beam and roof load to the base plateSection size, wall, internal chamber for the downpipe, base plate interface
Main beamHolds the blade pivots and carries the gutterDepth for the span, pivot spacing, gutter floor height, outlet position
BladeCloses the roof and sheds waterWidth, lip and notch on opposite edges, pivot slot position, stiffening ribs
Gutter insertCollects water from the blade endsSlope, capacity, outlet size, joint detail between bays
Seal retainerHolds the EPDM between blade and beamGroove width and depth, insertion direction
End cap and fasciaCloses the blade ends and hides the pivotFixing method, drainage weep holes
Motor housing, if motorisedTakes the shaft and the cableShaft clearance, cable route, service access

Not every roof needs every one of these. A wall-attached roof over a terrace usually drops the motor housing and one post line. A free-standing roof over a restaurant terrace needs all of them, plus a base plate detail that can take uplift.

A closed roof is a drainage system, not a lid

The complaint that repeats in owner forums is water standing in the middle of a closed roof, draining only when a blade is cracked open. It is not a cleaning problem. The roof was built flat.

Three features in the section decide whether water leaves.

Blade pitch in the closed position. The pivot slot sits below the blade centre line, so the blade closes to a slight slope rather than dead flat. That slope is drawn into the section, not set on site. If the pivot is centred, the closed roof is level and water sits until the wind moves it.

Lip and notch. One edge of the blade carries a lip, the opposite edge a matching notch. Closed, the lip of one blade sits inside the notch of the next, so water crosses the joint instead of falling through it. How much the lip overlaps sets how much rain the roof tolerates: 6 mm of overlap behaves very differently from 2 mm under wind-driven rain.

Gutter floor below the lowest blade edge. The beam gutter has to sit lower than the lowest point of a closed blade, or water has to run uphill to reach it. This sounds obvious, and it is the most common drawing error we see when a customer sends a section to quote.

Gutter size follows roof area, not habit. A 12 m² bay under 100 mm/h rain delivers about 1.2 m³ in that hour, and the outlet has to pass it in the same hour. On a long run, one outlet per bay beats one outlet at the end of a 12 m beam. If the downpipe runs inside the post, the post chamber is sized for the pipe before the die is cut; a solid post cannot be drilled out later without losing the wall that carries the load.

The blade that gets fitted upside down

Owners describe a roof that collects leaves and debris on top, and gutters that overflow in heavy rain. Sometimes the cause is a blade with a flat face and a shaped face and nothing to tell them apart. The installer puts the flat face up because it looks neater.

A section can prevent that. An asymmetric lip, a pivot slot offset from centre, a small rib on the up-face, or a keyed end cap that only fits one way. Any one of these makes the wrong assembly visible or impossible. We mark the up-face on the drawing and keep the marking in the die, so the difference survives powder coating, packing and a site where nobody reads the manual.

What Wall, Depth and Span Apply?

Structural profiles for a louvered roof are normally 2.0 to 3.0 mm wall. That range is a starting point, not a specification. What governs whether a beam sags is its depth and the span between posts, not the wall.

Bending stiffness rises with the cube of depth and only linearly with wall. Going from 2.5 mm to 3.0 mm adds 20% of material for roughly 20% more stiffness. Adding 40 mm of beam depth can more than double it at similar weight. Deflection goes with the fourth power of span, so a post spacing that grows from 3 m to 4 m does not add a third of the movement; it roughly triples it. When a design sags, the first lever is span, the second is depth, the third is a brace. Wall thickness is the last place to spend money.

We extrude on 26 presses from 500 to 5,000 MT, with a 540 mm maximum circumscribed circle, so a 265 mm blade with a deep stiffening box and a 200 mm post come out of the same plant. Grooves and seal seats are held to ±0.1 mm, because a seal groove that drifts 0.2 mm either will not take the EPDM or leaves it loose enough to whistle.

Finishes outdoors, including wood grain

Anodising, AA10 or AA15, is the finish that ages most predictably outside. The oxide is part of the metal, it does not chalk, and on a coastal site it is safer than a thin coat. Silver, champagne, bronze and black are standard.

Powder coating gives the colour range and is 60 to 80 µm on our line. Standard polyester holds up inland and in temperate climates. For a roof in the Gulf, in North Africa or in high-altitude sun, the specification should be a super-durable or HAA-class powder rather than the standard product, because the difference between the two shows up in year four, not year one.

Wood grain needs its own paragraph, because it is where buyers get caught.

Wood grain is a print. A film is applied over a powder base and transferred by heat, and the print layer is organic pigment. On a vertical wall in shade it can look convincing for a decade. On a horizontal roof in full sun it is the first thing to go: the film fades, the base colour shows through, and the roof turns patchy in two or three summers. This is not a defect of one supplier. It is what an unwarranted print does under UV.

A wood grain that is warranted for exterior use exists. It uses a qualified film over a super-durable or PVDF base, and it is tested to a colour-change limit over a stated number of hours. It also costs substantially more, often the largest single line in the finish column, and the warranty is only worth what the supplier will put in writing.

Our position, for a roof: anodised or solid powder on the blades, which take the most sun and the most water. Wood grain on posts and beams where they sit in shade, or on a wall-attached structure where the client accepts a shorter colour life. If wood grain has to go on the roof, budget for the warranted system, get the colour-change limit and the test hours into the contract, and keep a sealed sample. A cheap wood grain with a ten-year outdoor colour promise is a promise about the invoice, not the coating.

Lengths, cutting and packing

Blades and beams ship cut to your cutting list. A 40 ft container takes 6.0 m, a 20 ft container 5.85 m, and cuts under 5 m carry a sawing charge. For a roof, cutting to length at the plant removes the joint that would otherwise sit in the middle of a blade, which is where a roof leaks first.

A blade is a wide, thin section. It is packed face to face with interleaving, ends on foam, and bundles labelled to match the packing list. Bent blade ends are the most common transport damage on this product, and they stay invisible until the first bay is assembled.

What we do not supply

Motors, sensors, remote controls, zip screens, glass, fixings and installation. We also do not sell finished pergolas. If you are a fabricator or a system brand, this is deliberate: you keep the assembly, the brand and the customer, and buy the extruded parts, cut and finished, at a profile price. Minimum order is 500 kg per profile; a first roof set is normally several tonnes across the family.

Related profiles and reading

Warranty and Claims

Profiles are warranted for 10 years against dimensional non-conformance to the approved drawing, material defects in the extrusion, and adhesion or chalking failure of the anodised or powder-coated surface under normal service. A claim starts with the bundle number and the mill certificate; we replace or credit non-conforming bundles and cover the freight on a verified defect. The warranty does not cover site damage, cutting, welding, or mechanical damage after delivery.

Payment, HS Code and Export Markets

  • Payment: 30% deposit, 70% against copy B/L or before shipment, by T/T (small EXW orders settled before shipment).
  • HS code: 7604.21 (hollow aluminium profiles); 7604.29 (other aluminium profiles); 7608.20 (aluminium tubes and pipes).
  • Markets: Mexico, Colombia, Chile, Argentina, South Africa, Nigeria, Kenya, Egypt, Saudi Arabia, UAE and Indonesia.

New die & sample: 10–20 working days, including die trial and sampling.

Reviewed 2026-11-10 · Linkedalu Metal Group Co., Ltd (production: Foshan, Guangdong; head office: Xiamen; since 2005) · 26 presses (500–5000 MT), 100,000 t/year.

Technical guides for these profiles

Two questions decide most of these orders: how tight the section can be held, and what the finish does to the finished dimensions. These guides answer both, with the tolerances and alloy data we hold in the plant.

Typical applications

  • check Terraces and patios, hotel and restaurant outdoor seating, poolside shading, residential gardens, wall-attached verandas, car park and walkway canopies.

Architectural Aluminum · Sunroom & Screen Room Profiles

Aluminium Pergola and Louvered Roof Profiles for Outdoor Structures

Extruded posts, beams, louver blades and internal gutters for louvered roofs. Blades 130-265 mm, structural walls 2.0-3.0 mm, cut to your list.

Technical parameters

Material 6063-T5 / T6, 6061 on request
Blade width 130-265 mm
Structural wall 2.0-3.0 mm
Max circumscribed circle 540 mm
Groove and seal seat ±0.1 mm
Finishes Anodised AA10 / AA15, powder 60-80 µm, wood grain
Lengths Cut to your cutting list, 6.0 m maximum
MOQ 500 kg per profile
Press line 26 presses, 500-5000 MT
Terms FOB Shenzhen / Guangzhou
Alloy 6063
Application Operable louver systems Residential sunrooms and conservatories Screenrooms and patio enclosures
Surface finish Anodized Powder coated Wood grain
Industry Architecture Residential Sun Shading
Standard EN 755 GB/T 5237
Temper T5 T6
  • verified_userMill test report supplied with every shipment
  • scheduleTypical lead time 15–25 days after die approval
  • publicExport packing, FOB Shenzhen / Guangzhou

Technical FAQ

Can you supply the whole profile family, or only blades? add
The whole family: posts, beams, blades, gutter insert, seal retainer and end caps, from one die shop, so the fits are drawn against each other rather than assembled from three suppliers. Motors and screens are not ours.
Which blade width should I specify? add
Between 130 and 265 mm, driven by bay width, the open area you need and how deep a stack you can accept when the roof is open. A wider blade means fewer pivots and fewer joints but more water per blade and a deeper stack. Send the bay layout and we will check the section against it.
How do I stop water standing on a closed roof? add
Three things: pivot below centre so the closed blade has slope, lip-and-notch overlap at the joint, and a gutter floor below the lowest blade edge. All three are in the drawing. If a supplier's section is flat when closed, no amount of site adjustment fixes it.
Is wood grain suitable for an outdoor pergola? add
Standard wood-grain transfer fades under direct UV, fastest on a horizontal roof. A warranted exterior system exists and costs significantly more. For blades, anodised or solid powder is the honest choice; wood grain belongs on shaded posts and beams unless the budget carries the warranted film.
What wall thickness do you recommend for posts? add
2.0 to 3.0 mm is the normal structural range, set by span, wind uplift and the base fixing rather than by habit. Going to 3.0 mm does not rescue a 4 m span that needs a deeper beam or a closer post.
Do you supply complete kits? add
No. Profiles, cut to length, punched, notched, anodised or powder coated, packed for export, FOB Shenzhen or Guangzhou. Assembly, hardware and motors are yours.

Customer cases and reviews

No reviews yet — be the first to review Aluminium Pergola and Louvered Roof Profiles.

Write a review

Write a review

Reviews are read by our team before they appear here, usually within one working day. We publish what customers write; we only remove spam and abuse.

Held for moderation before it is published.

Request a quotation for this profile

Include your drawing reference, alloy, finish, quantity and destination port. If you have a DXF or PDF, mention it in the message and we will request it by email.

Drawings & CAD files: email DWG, DXF, STEP or PDF to sales@linkedalu.com?subject=Profile%20drawing%20for%20quotation">sales@linkedalu.com — they are quoted together with this request.

Or email sales@linkedalu.com

Why engineers buy this profile from us

  • Die design in-house. Our tooling engineers balance metal flow before the first billet is pressed, which keeps wall thickness and straightness repeatable order after order.
  • One partner for finishing. Extrusion, anodizing, coating, machining and assembly happen on one site, so tolerances are not lost between suppliers.
  • Documentation that clears customs and auditors. Composition, mechanical properties, dimensional and coating reports ship with the goods.
  • Stable supply. 100,000 tonnes of annual capacity and 26 presses mean your schedule is not hostage to a single line.
About our factoryarrow_forward