We extrude the parts that make a louvered roof: posts, main beams, blades, the gutter that sits inside the beam, seal retainers and end caps. Blades run from 130 to 265 mm, structural profiles from 2.0 to 3.0 mm wall, in 6063-T5 or T6, cut to your list and finished anodised or powder coated. We supply profiles. Motors, screens, glass and installation stay with you.
Two things decide whether a louvered roof still works after the second rainy season: where the water goes when the blades are closed, and whether a blade can be fitted the wrong way up. Both are settled in the section drawing, long before anyone stands on a ladder.
What Does a Roof Set Contain?
A complete louvered roof is not one profile. It is a small family of sections that have to fit each other, and each one carries a decision.
| Profile | What it does | What the drawing has to fix |
| Post | Carries beam and roof load to the base plate | Section size, wall, internal chamber for the downpipe, base plate interface |
| Main beam | Holds the blade pivots and carries the gutter | Depth for the span, pivot spacing, gutter floor height, outlet position |
| Blade | Closes the roof and sheds water | Width, lip and notch on opposite edges, pivot slot position, stiffening ribs |
| Gutter insert | Collects water from the blade ends | Slope, capacity, outlet size, joint detail between bays |
| Seal retainer | Holds the EPDM between blade and beam | Groove width and depth, insertion direction |
| End cap and fascia | Closes the blade ends and hides the pivot | Fixing method, drainage weep holes |
| Motor housing, if motorised | Takes the shaft and the cable | Shaft clearance, cable route, service access |
Not every roof needs every one of these. A wall-attached roof over a terrace usually drops the motor housing and one post line. A free-standing roof over a restaurant terrace needs all of them, plus a base plate detail that can take uplift.
A closed roof is a drainage system, not a lid
The complaint that repeats in owner forums is water standing in the middle of a closed roof, draining only when a blade is cracked open. It is not a cleaning problem. The roof was built flat.
Three features in the section decide whether water leaves.
Blade pitch in the closed position. The pivot slot sits below the blade centre line, so the blade closes to a slight slope rather than dead flat. That slope is drawn into the section, not set on site. If the pivot is centred, the closed roof is level and water sits until the wind moves it.
Lip and notch. One edge of the blade carries a lip, the opposite edge a matching notch. Closed, the lip of one blade sits inside the notch of the next, so water crosses the joint instead of falling through it. How much the lip overlaps sets how much rain the roof tolerates: 6 mm of overlap behaves very differently from 2 mm under wind-driven rain.
Gutter floor below the lowest blade edge. The beam gutter has to sit lower than the lowest point of a closed blade, or water has to run uphill to reach it. This sounds obvious, and it is the most common drawing error we see when a customer sends a section to quote.
Gutter size follows roof area, not habit. A 12 m² bay under 100 mm/h rain delivers about 1.2 m³ in that hour, and the outlet has to pass it in the same hour. On a long run, one outlet per bay beats one outlet at the end of a 12 m beam. If the downpipe runs inside the post, the post chamber is sized for the pipe before the die is cut; a solid post cannot be drilled out later without losing the wall that carries the load.
The blade that gets fitted upside down
Owners describe a roof that collects leaves and debris on top, and gutters that overflow in heavy rain. Sometimes the cause is a blade with a flat face and a shaped face and nothing to tell them apart. The installer puts the flat face up because it looks neater.
A section can prevent that. An asymmetric lip, a pivot slot offset from centre, a small rib on the up-face, or a keyed end cap that only fits one way. Any one of these makes the wrong assembly visible or impossible. We mark the up-face on the drawing and keep the marking in the die, so the difference survives powder coating, packing and a site where nobody reads the manual.
What Wall, Depth and Span Apply?
Structural profiles for a louvered roof are normally 2.0 to 3.0 mm wall. That range is a starting point, not a specification. What governs whether a beam sags is its depth and the span between posts, not the wall.
Bending stiffness rises with the cube of depth and only linearly with wall. Going from 2.5 mm to 3.0 mm adds 20% of material for roughly 20% more stiffness. Adding 40 mm of beam depth can more than double it at similar weight. Deflection goes with the fourth power of span, so a post spacing that grows from 3 m to 4 m does not add a third of the movement; it roughly triples it. When a design sags, the first lever is span, the second is depth, the third is a brace. Wall thickness is the last place to spend money.
We extrude on 26 presses from 500 to 5,000 MT, with a 540 mm maximum circumscribed circle, so a 265 mm blade with a deep stiffening box and a 200 mm post come out of the same plant. Grooves and seal seats are held to ±0.1 mm, because a seal groove that drifts 0.2 mm either will not take the EPDM or leaves it loose enough to whistle.
Finishes outdoors, including wood grain
Anodising, AA10 or AA15, is the finish that ages most predictably outside. The oxide is part of the metal, it does not chalk, and on a coastal site it is safer than a thin coat. Silver, champagne, bronze and black are standard.
Powder coating gives the colour range and is 60 to 80 µm on our line. Standard polyester holds up inland and in temperate climates. For a roof in the Gulf, in North Africa or in high-altitude sun, the specification should be a super-durable or HAA-class powder rather than the standard product, because the difference between the two shows up in year four, not year one.
Wood grain needs its own paragraph, because it is where buyers get caught.
Wood grain is a print. A film is applied over a powder base and transferred by heat, and the print layer is organic pigment. On a vertical wall in shade it can look convincing for a decade. On a horizontal roof in full sun it is the first thing to go: the film fades, the base colour shows through, and the roof turns patchy in two or three summers. This is not a defect of one supplier. It is what an unwarranted print does under UV.
A wood grain that is warranted for exterior use exists. It uses a qualified film over a super-durable or PVDF base, and it is tested to a colour-change limit over a stated number of hours. It also costs substantially more, often the largest single line in the finish column, and the warranty is only worth what the supplier will put in writing.
Our position, for a roof: anodised or solid powder on the blades, which take the most sun and the most water. Wood grain on posts and beams where they sit in shade, or on a wall-attached structure where the client accepts a shorter colour life. If wood grain has to go on the roof, budget for the warranted system, get the colour-change limit and the test hours into the contract, and keep a sealed sample. A cheap wood grain with a ten-year outdoor colour promise is a promise about the invoice, not the coating.
Lengths, cutting and packing
Blades and beams ship cut to your cutting list. A 40 ft container takes 6.0 m, a 20 ft container 5.85 m, and cuts under 5 m carry a sawing charge. For a roof, cutting to length at the plant removes the joint that would otherwise sit in the middle of a blade, which is where a roof leaks first.
A blade is a wide, thin section. It is packed face to face with interleaving, ends on foam, and bundles labelled to match the packing list. Bent blade ends are the most common transport damage on this product, and they stay invisible until the first bay is assembled.
What we do not supply
Motors, sensors, remote controls, zip screens, glass, fixings and installation. We also do not sell finished pergolas. If you are a fabricator or a system brand, this is deliberate: you keep the assembly, the brand and the customer, and buy the extruded parts, cut and finished, at a profile price. Minimum order is 500 kg per profile; a first roof set is normally several tonnes across the family.
Related profiles and reading
Warranty and Claims
Profiles are warranted for 10 years against dimensional non-conformance to the approved drawing, material defects in the extrusion, and adhesion or chalking failure of the anodised or powder-coated surface under normal service. A claim starts with the bundle number and the mill certificate; we replace or credit non-conforming bundles and cover the freight on a verified defect. The warranty does not cover site damage, cutting, welding, or mechanical damage after delivery.
Payment, HS Code and Export Markets
- Payment: 30% deposit, 70% against copy B/L or before shipment, by T/T (small EXW orders settled before shipment).
- HS code: 7604.21 (hollow aluminium profiles); 7604.29 (other aluminium profiles); 7608.20 (aluminium tubes and pipes).
- Markets: Mexico, Colombia, Chile, Argentina, South Africa, Nigeria, Kenya, Egypt, Saudi Arabia, UAE and Indonesia.
New die & sample: 10–20 working days, including die trial and sampling.
Reviewed 2026-11-10 · Linkedalu Metal Group Co., Ltd (production: Foshan, Guangdong; head office: Xiamen; since 2005) · 26 presses (500–5000 MT), 100,000 t/year.