Skip to main content
Linkedalu Metal Group Co., Ltd LINKEDALU Metal Group
Black anodised aluminium U-channel profile, three-quarter view of the slot and both legs

A U-channel size is written as outside width × leg height × wall thickness, and the wall sets the weight: 40 × 25 × 2 mm is 172 mm² of metal at 0.464 kg/m, so a tonne runs 2,153 m. Walls start at 0.8 mm, the minimum is 500 kg per section, and lengths are cut to your list — 5.85 m is the longest that fits a 20 ft container.

Order facts for a U-channel run

ItemCondition
Minimum order500 kg per section, whether or not a new die is required; one order is 5 t and can mix sections and colours; powder-coated and wood-grain colours are 2 t per colour
CuttingTo your cutting list and labelled by elevation; pieces under 5 m carry a sawing charge
Container20 ft 5.85 m · 40 ft 6.0 m in two lengths · 45 ft 6.4 m, few services
New die and sample10–20 working days, die trial and sample included
Lead time15–25 days after die approval
Payment30% deposit, 70% against copy B/L or before shipment, by T/T
Trade termFOB Shenzhen / Guangzhou

How Is a U-Channel Size Written?

Size is outside width × outside leg height × wall thickness, in that order. Inner width is the outside width minus twice the wall.

Most confusion starts at the order of the first two numbers and at which face is measured. A 40 × 25 × 2 mm section is 40 mm across the base and 25 mm up the legs; a drawing marked 25 × 40 is a different section and a different die. Measure outside faces, because that is how the blank is checked and how the mating part is built to clear it. The wall is usually uniform, and where a leg has to carry a screw thread or a hinge it can be thicker without changing the outside.

Why There Is No Standard U-Channel Size Chart

We hold no stock range: every section is extruded to a drawing, so a published standard size list would be arithmetic, not a catalogue.

The size charts published by other mills are photographs of their own die libraries. Buying from one means accepting their slot depth, their inside corner radius and their alloy heat, and paying for a die that already exists rather than one that fits your glass or panel. The reference table below is calculated from nominal geometry, so you can size the section and estimate the freight before you draw anything. The die is then cut to your section, and the drawing — not the table — is what gets quoted.

Reference Sections and Weight per Metre

A 15 × 15 × 1.5 mm section weighs 0.170 kg/m and a 100 × 50 × 5 mm section weighs 2.565 kg/m; everything between is the same arithmetic on the same basis.

Weights below are theoretical, on nominal geometry with sharp internal corners at a density of 2.70 g/cm³, before anodising or coating. This is not a stock list and none of these sections is held in inventory. Bundle weight is certified on the mill test certificate, and the extrusion weight tolerance is ±10%, so the certified weight settles the order — not the calculated one.

Outside width (mm)Leg height (mm)Wall (mm)Area (mm²)Weight (kg/m)Ix (cm⁴)Iy (cm⁴)Inner width (mm)Metres per tonne
15151.563.00.1700.140.23125,879
19192.0106.00.2860.390.61153,494
25252.0142.00.3830.911.48212,608
30252.0152.00.4100.982.26262,437
40252.0172.00.4641.084.39362,153
40403.0342.00.9235.669.21341,083
50253.0282.00.7611.6410.42441,313
60303.0342.00.9232.9218.57541,083
100505.0950.02.56522.50143.2990390

Ix is taken about the axis through the base, so it describes the section standing on its base with the load applied across the legs. Iy is about the vertical axis. Both are calculated about the centroid and ignore the corner fillets, which add a little material.

Leg Height Buys Stiffness; Wall Thickness Buys Weight

40 × 40 × 3 and 60 × 30 × 3 weigh the same 0.923 kg/m, but the taller leg is 94% stiffer across the load axis — Ix 5.66 against 2.92 cm⁴.

That one comparison settles most of these enquiries. Going from a 2 mm to a 4 mm wall on a 30 × 25 section adds 89% to the weight and 77% to Ix: you pay nearly a tonne per tonne for stiffness you could have bought by making the legs longer. Thicken the wall when the failure is local — a tapped hole, a screw seated in a 1 mm leg, a roller bearing on one spot, a section that will be clamped.

The ranking reverses about the other axis, and that is not a defect. 60 × 30 × 3 has twice the Iy of 40 × 40 × 3 because more material sits away from the vertical axis. A wide shallow channel resists sideways load, the way a track fixed to a wall is loaded; a narrow deep one resists the load applied to its opening. Say which way it is loaded and the table picks the section.

Which Slot Width Takes the Glass You Are Glazing?

Slot width is the glass plus the setting material on each side. 10 mm glass with 1 mm each side needs a 12 mm inner width — the 15 × 15 × 1.5 mm section.

The inner width column is the number a glazier works to, and it is missing from most drawings. Set it from the glass and from the tape or gasket actually being used: a dry-glazed balustrade shoe and a wet-glazed shopfront arrive at different slots for the same glass. Keep the inside corner small and clean, because a sharp corner chips the edge of the glass on the way in, and hold the legs parallel — the glass bears on them, and a leg that leans closes the slot at the bottom only.

Anodising inside and out in AA10 or AA15 is the usual finish for visible glazing, because the slot shows as soon as the panel is set. Powder coating suits sections that will not be cut on site, since a cut end exposes bare metal.

What Fits in a 20 ft or 40 ft Container?

A 20 ft container takes 5.85 m, a 40 ft takes 6.0 m in two lengths, and a 45 ft reaches 6.4 m but few services call at the ports we ship to.

Length is rarely the limit. At 0.464 kg/m a 5 t order is 10,776 m — about 1,842 pieces at 5.85 m — and no container holds that many pieces. At 2.565 kg/m the same 5 t is 1,949 m, or 333 pieces, and the payload arrives long before the length does. That is why the metres-per-tonne column matters more than the nominal size: it tells you which limit you hit first.

Anything under 5 m carries a sawing charge, because short pieces take the same set-up and produce more offcut. Send the piece lengths and the sequence and we pack in that order, so the crate can be worked from the top down on site.

What Tolerance Applies to the Slot and the Leg Height?

Every dimension is held to GB/T 5237 high-precision grade and the weight to ±10% of nominal; faces that must mate are machined after extrusion.

We do not publish a millimetre table against a grade, because the grade is the contract and a table of invented values is the first thing a buyer checks and the reason he closes the page. High-precision grade covers the cross-section, the straightness, the twist and the angle between leg and base. Where a mating face needs more than the grade gives, it is machined after extrusion rather than squeezed out of the die. Tighter extrusion tolerance also slows the press and adds inspection, so the useful question is what the assembly does with the face: a slot the glazier shims does not need what a track the roller rides on needs.

From Drawing to Crate

Send the section drawing with the size written as outside width × leg height × wall, the alloy and temper, the finish, the piece lengths and the quantity. We check the drawing for wall ratios that will warp and for faces that will need machining, and answer with the die cost, the section weight and the container plan. The die is cut and trialled, the sample is approved — 10–20 working days for die and sample together — and production runs 15–25 days after approval. Cutting, drilling, slotting and punching are done in-house on the same site as extrusion and finishing, and pieces are labelled to your cutting list and packed in sequence.

Alloys in regular production are 6063 and 6061; other alloys are produced on request.

What We Cannot Do

  • We do not hold a stock range of U-channel and we do not publish a standard size chart: every section is extruded to a drawing.
  • We do not supply glass, gaskets, setting tape, fasteners or the assembled frame.
  • We do not certify a structural, wind or load rating without the span, the fixing layout and the load class.
  • We do not quote a firm price against a sketch without the alloy, the wall thickness and the finish.
  • We do not guess the slot from the glass: send the glass thickness and the tape, and the slot follows.

Technical guides for these profiles

Typical applications

  • check Glass retention and balustrade base shoes
  • check Panel and ACM receivers
  • check Sliding tracks and machine guides
  • check Edge trim and reveals
  • check Cable management
  • check Light structural framing

Standard Aluminum Shapes · U-Channel Profiles

U-Channel Sizes Calculated to Your Drawing, Not a Stock List

Reference U-channel sections with weight per metre, inner width and container loads, extruded to your drawing — 500 kg per section, cut to your cutting list.

Technical parameters

Size call-out Outside width × leg height × wall thickness
Weight per metre 0.170–2.565 kg/m on the reference set, at 2.70 g/cm³
Wall thickness From 0.8 mm
Inner width Outside width minus twice the wall
Section properties Ix 0.14–22.50 cm⁴, Iy 0.23–143.29 cm⁴
Alloy & temper 6063 and 6061; other alloys produced on request
Tolerance GB/T 5237 high-precision grade; weight ±10%; faces that must mate are machined after extrusion
Length Cut to your cutting list; 5.85 m in a 20 ft, 6.0 m in a 40 ft
Finish Anodising in AA10 or AA15; powder coating; other systems on request
Minimum order 500 kg per section, whether or not a new die is required
Alloy 6061 6063
Application ACM and HPL panel receivers Atrium and skylight framing Balcony glass balustrades Commercial track rails and wall washer bodies Frameless glass retention and storefront glazing Industrial screening panels Panel stiffeners on doors and machine guards Partition and shopfront framing Point-supported glass facades Poolside glass railings Shopfront and partition framing Sliding door tracks and panels Sliding tracks and cable carriers Sliding window and door tracks Structural framing and bracing
Surface finish Anodized Mill finish Powder coated
Industry Framing channels General fabrication Industrial equipment
Standard GB/T 5237
Temper T5 T6
  • verified_userMill test report supplied with every shipment
  • scheduleTypical lead time 15–25 days after die approval
  • publicExport packing, FOB Shenzhen / Guangzhou

Technical FAQ

How is aluminium U-channel measured? add
Outside width × outside leg height × wall thickness, in millimetres, taken on the outside faces. Inner width, which is what a panel or glass fits into, is the outside width minus twice the wall.
How do I calculate the weight of a U-channel per metre? add
Take the cross-sectional area in mm² and multiply by 0.0027 to get kg/m. A 40 × 25 × 2 mm section is 172 mm², so 0.464 kg/m, and a tonne is 2,153 m. Certified bundle weight is on the mill test certificate and holds to ±10%.
Do you keep U-channel sizes in stock? add
No. Every section is extruded to a drawing and there is no inventory of standard U-channel. The reference table on this page is geometry for sizing, not a list of sections we hold.
What is the smallest wall thickness you can extrude? add
0.8 mm. The upper limit depends on the section and the alloy, so send the drawing rather than asking for a maximum — a 5 mm base with 5 mm legs behaves differently from 5 mm in one face only.
What is the minimum order for one U-channel size? add
500 kg per section, whether or not a new die is needed. One order is 5 t and can mix sections and colours; powder-coated and wood-grain colours are 2 t per colour.
How many metres of U-channel fit in a 20 ft container? add
5.85 m is the longest length that loads, so the question becomes how many pieces. At 0.464 kg/m a 5 t order is 10,776 m — 1,842 pieces at 5.85 m — and the container runs out of payload long before it runs out of length.
Which slot do I need for 10 mm glass? add
Glass plus the setting material on each side. 10 mm glass with 1 mm each side needs 12 mm inner width, which the 15 × 15 × 1.5 mm section gives; with a 3 mm gasket in total it needs 13 mm and the next size up. Tell us both numbers and we size the slot.
Can you cut to my cutting list and label each piece? add
Yes. Cutting, drilling, slotting and punching are in-house, pieces are labelled to your elevation or call-up list, and they are packed in sequence so the installer works straight from the crate. Lengths under 5 m carry a sawing charge.

Customer cases and reviews

No reviews yet — be the first to review Aluminum U-Channel Sizes and Weights.

Write a review

Write a review

Reviews are read by our team before they appear here, usually within one working day. We publish what customers write; we only remove spam and abuse.

Held for moderation before it is published.

Request a quotation for this profile

Include your drawing reference, alloy, finish, quantity and destination port. If you have a DXF or PDF, mention it in the message and we will request it by email.

Drawings & CAD files: email DWG, DXF, STEP or PDF to sales@linkedalu.com?subject=Profile%20drawing%20for%20quotation">sales@linkedalu.com — they are quoted together with this request.

Or email sales@linkedalu.com

Why engineers buy this profile from us

  • Die design in-house. Our tooling engineers balance metal flow before the first billet is pressed, which keeps wall thickness and straightness repeatable order after order.
  • One partner for finishing. Extrusion, anodizing, coating, machining and assembly happen on one site, so tolerances are not lost between suppliers.
  • Documentation that clears customs and auditors. Composition, mechanical properties, dimensional and coating reports ship with the goods.
  • Stable supply. 100,000 tonnes of annual capacity and 26 presses mean your schedule is not hostage to a single line.
About our factoryarrow_forward