Short answer. We extrude curtain wall mullions, transoms, pressure plates, cover caps, corner sections and sill details in 6063-T5/T6, with walls from 1.2 mm to 6.0 mm and mill lengths of 6.0–7.0 m. Thermal-break assembly, CNC drilling and tapping run in the same plant in Foshan. Minimum order is 500 kg per profile, and profiles ship FOB Shenzhen or Guangzhou, cut to your list.
The choice that decides everything else is unitized or stick-built. Unitized moves assembly to the factory and puts the tolerance on the panel; stick-built keeps assembly on site and puts it on the mullion. Pick that first, then the mullion depth.
Unitized or Stick-Built
| What you are building | System to specify | What the section has to solve | Where we go deeper |
| Tower with a fixed panel module, factory glazing | Unitized | Panel tolerance stack-up, interlock water path, crane and floor-loading sequence | High-rise curtain wall profiles |
| Low- to mid-rise, site glazing, irregular grid | Stick-built | Mullion depth for wind load, transom fixing, site tolerance allowance | Architectural curtain wall profiles |
| Renovation over an existing frame | Stick-built, shallow | Cover cap interface, fixing into an unknown substrate | Architectural curtain wall profiles |
| Narrow sightline with a visible mullion | Unitized, split mullion | Sightline width against drainage chamber depth | High-rise curtain wall profiles |
Mullion Depth and Wind Load
Mullion depth is set by wind load and span, not by the glass. A deeper mullion raises the section modulus and the moment of inertia together, which is why two facades with the same glass can need different sections. Wall thickness then follows the depth: a 1.2 mm wall is common on low-rise stick-built work, and 3.0 mm and above appears on exposed towers where the section is also handling thermal movement.
Questions Before Ordering
Which alloy is used for curtain wall profiles? 6063-T5 and 6063-T6 for most mullions and transoms, 6061 where a higher-strength section is needed. All three are extruded in Foshan.
What wall thickness do curtain wall mullions need? Most specifications land between 1.2 mm and 6.0 mm, set by wind load and mullion depth rather than a fixed rule. Our plant extrudes from 0.8 mm up.
What is the largest profile you can supply? Up to a 540 mm circumscribed circle on a 5,000 MT press, with mill lengths of 6.0–7.0 m. A 40 ft container takes 6.0 m profiles in two cuts.
Can you supply thermal-break curtain wall profiles? Yes. Profiles are extruded, then cut and assembled with polyamide strips in the same plant, with CNC drilling and tapping after assembly.
What is the minimum order? 500 kg per profile, whether the die is new or already in our rack. A new die takes 15–25 working days after drawing approval, plus 3–5 days for sampling.