Skip to main content
Linkedalu Metal Group Co., Ltd LINKEDALU Metal Group
Curtain Wall Profiles for High-Rise Projects

Curtain Wall Framing Engineered for Tall Buildings

Linkedalu Metal Group Co., Ltd extrudes custom curtain wall framing for high-rise projects: vertical mullions, horizontal transoms, exterior pressure plates and cover caps. On a tall building the curtain wall is not an envelope applied to a frame — it moves with that frame, resists the same wind load and has to keep water and air out while it does so. We work from your shop drawings and extrude to the alloy, temper and coating the specification calls out, so the engineer who approves those drawings gets exactly the material that reaches site.

One Material Lot, Three Standards

High-rise specifications travel. A tower in South America may be written to a national code, while the same facade package is procured against European or American material standards. We run one set of dies, one billet batch and one coating line, then issue mill test certificates against GB/T 5237, EN 755-9 and ASTM B221 from that same material. The result is one documented lot that can be accepted under whichever standard governs the project, without a second extrusion run or a color mismatch between deliveries.

Designing for the Region, Not Just the Product

Curtain wall performance is regional. The loads that matter, the code that governs and the corrosion environment all differ, so we tune the section accordingly:

  • Seismic zones. In Chile, where towers are designed to NCh 433, the curtain wall must follow the structural frame through inter-story drift without tearing glass, breaking gaskets or leaking at the joint. That drives the design of the glazing register, the depth of the mullion engagement and the amount of movement the pressure plate allows.
  • Coastal and salt-laden air. Pacific and Gulf coastal sites need coating build and alloy selection chosen for corrosion, not only for color.
  • Hot-humid and high-wind climates. Southeast Asian projects combine typhoon wind pressures with heavy rainfall, so drainage paths, baffles and glazing gasket compression matter as much as section strength.

Section Review Before the Die Is Cut

Before committing a die, our engineers check the proposed section against your loads. Moment of inertia is compared with wind load and deflection limits, and where the geometry allows we suggest a wall thickness or alloy change that reaches the same performance with less material. Because the review happens at drawing stage, changes cost nothing at site.

How a High-Rise Order Moves Through the Mill

  • You send shop drawings: cross-sections, fabrication list, surface finish and target standard (GB, EN or ASTM).
  • We verify the section against wind load and deflection limits and confirm the die or propose a revision.
  • Billets are cast and logged, and the order is locked to a single batch.
  • Extrusion, straightening and cut-to-length run together with the coating line for the same project.
  • CNC machining follows: miter sawing, drainage slotting, bolt-hole drilling, tapping and milling.
  • Profiles are labeled and packed in sequence, with mill test certificates and packing lists issued against bundle labels.

Traceability From Bundle to Billet

Packing lists are tied to your bundle labels, so every cut length can be traced back to the billet batch and the coating run it came from. If a question arises on site about a specific frame member, the material history is retrievable rather than reconstructed.

Alloy and Finish Options

6063-T5 is the standard alloy for this product family: it extrudes cleanly across deep multi-cavity mullion sections and anodizes evenly. Anodizing and PVDF are the usual finishes for high-rise facades, chosen by exposure — anodizing where a metallic appearance and abrasion resistance are wanted, PVDF where color stability and gloss retention matter over decades of sunlight and salt spray. Both are applied over the same verified alloy and temper so the certificate and the appearance correspond.

Typical applications

  • check High-rise office towers
  • check Seismic-zone curtain walls
  • check Coastal high-rise facades
  • check Stick and unitized facade systems
  • check Commercial mixed-use towers
  • check Tropical high-wind facades

Architectural Aluminum · Curtain Wall Profiles

Curtain Wall Profiles for High-Rise Projects

Custom-extruded curtain wall framing for high-rise towers — one die set, one billet batch, one coating line, documented to GB/T 5237, EN 755-9 or ASTM B221 from the same material.

Technical parameters

Alloy & Temper 6063-T5
Profile Type Curtain wall mullions, transoms, pressure plates, cover caps
Wall Thickness 1.2 mm - 6.0 mm
Tolerance GB/T 5237 high-precision class
Surface Finish Anodizing, PVDF coating
Length 6.0 m standard, cut to project length
Fabrication Miter sawing, CNC drilling, milling, tapping, drainage slotting
MOQ 500 kgs
Lead Time Confirmed at order after drawing and die approval
Standards GB/T 5237, EN 755-9, ASTM B221
Alloy 6063
Application Coastal high-rise facades High-rise office towers Seismic-zone curtain walls Stick and unitized facade systems
Surface finish Anodized Pvdf Coated
Industry Architecture Construction Facades
Standard ASTM B221 EN 755 GB/T 5237
Temper T5
  • verified_userMill test report supplied with every shipment
  • scheduleTypical lead time 15–25 days after die approval
  • publicExport packing, FOB Xiamen / CIF / DDP

Technical FAQ

Can one material lot be certified to GB, EN and ASTM standards? add
Yes. We run one set of dies, one billet batch and one coating line, then issue mill test certificates against GB/T 5237, EN 755-9 and ASTM B221 from that same material. This means the engineer approving your shop drawings receives exactly the alloy, temper and coating specified, whichever material standard the project is written to.
How do you handle seismic movement in a high-rise curtain wall? add
In seismic regions such as Chile, where towers are designed to NCh 433, the curtain wall must follow the structural frame through inter-story drift without tearing glass or leaking. We address this in the section geometry: the glazing register, the depth of mullion engagement and the movement allowance built into the pressure plate and gasket compression.
What information do you need to quote a high-rise facade package? add
Send shop drawings with cross-sections, your fabrication list, the required surface finish and the target standard — GB, EN or ASTM. With those we can verify each section against your wind load and deflection limits, confirm the die or propose a wall-thickness or alloy change, and quote the complete bill of materials.
Is machining available before the profiles are packed? add
Yes. CNC deep processing covers precision miter sawing to fixed length, connector pin milling, drainage slotting, bolt-hole drilling and tapping. Delivering pre-machined profiles limits on-site fabrication error and field labor cost, and each cut length stays traceable to its bundle label, billet batch and coating run.

Customer reviews

5.0 out of 5 · 1 review
Write a review
  • Tufei

    It is a great product

    Reviewed Sep 16, 2026

Write a review

Reviews are read by our team before they appear here, usually within one working day. We publish what customers write; we only remove spam and abuse.

Held for moderation before it is published.

Request a quotation for this profile

Include your drawing reference, alloy, finish, quantity and destination port. If you have a DXF or PDF, mention it in the message and we will request it by email.

Drawings & CAD files: email DWG, DXF, STEP or PDF to sales@linkedalu.com — they are quoted together with this request.

Or email sales@linkedalu.com

Why engineers buy this profile from us

  • Die design in-house. Our tooling engineers balance metal flow before the first billet is pressed, which keeps wall thickness and straightness repeatable order after order.
  • One partner for finishing. Extrusion, anodizing, coating, machining and assembly happen on one site, so tolerances are not lost between suppliers.
  • Documentation that clears customs and auditors. Composition, mechanical properties, dimensional and coating reports ship with the goods.
  • Stable supply. 100,000 tonnes of annual capacity and 26 presses mean your schedule is not hostage to a single line.
About our factoryarrow_forward